Power supply issues
PWR LED remains off
The iMux system isn’t receiving proper power.
AC power
• Check AC power using a multimeter.
DC power
• Check power at the DC terminals using a multimeter.
• No AC power can be detectable on the DC power line.
• Check wiring for nicking, scoring or poor termination.
Verifying fiber cable
Verify the fiber cable when incoming signal is good, but the other end indicates that a fiber signal is not being
received. To test the fiber cable, use a fiber optic cable test set with light source and meter.
iMux System Fiber Test Specifications
When reconnecting fiber cables, check the correct connection of the fiber cable.
Module installation
The iMux comes standard with modules pre-installed and pre-configured. When replacing or installing any
modules, use caution to ensure that
• The modules are fully inserted without damaging any components on the circuit board
• The locking screws are completely seated and hand tightened only
• The breakout adapter cables (where used) are properly connected and seated
• The optical modules are protected at all times with dust cap or fiber connector installed
• Special handling requirements are observed
If the iMux module configuration is changed, or modules are moved to a different tributary slot, the system must
be reconfigured accordingly using the VT100 management interface.
Troubleshooting! 115